Description
Drill-Tek 175c MWD System offers:
Positive Pulse or EM telemetry.
Integrated platform, software and hardware.
Seamless integration with Hunter Twin™ EM system.
Motor driven pulsers for reliability, performance and ease of use.
Operator selectable programming.
Gamma, Resistivity, Pressure while drilling available.
Long battery life.
Easy to maintain.
Built on the industry expandable Tensor platform.
Improved detection in noisy environments.
Wireless design with redundant wired system.
Easy to use.
Technologically advanced
Low consumption electronics
High reliability design
Expansion inputs allow for future additions
Compatibility
Designed and tested to be Qbus and XXbus compatible
No modifications required to connect to industry standard Tensor equipment
Uses common MWD spares for repair and maintenance
175C MWD GAMMA KIT SPECIFICATIONS (RETRIEVABLE KIT) | |||
KINTECS / GAMMA MWD TOOL SPECIFICATIONS | Tool Features | Drill-Tek Specs | |
Telemetry Type | +VE | ||
Tool Outer Diameter | 47.49 mm | ||
Length of Tool | (a) Directional Only | 6.75 Meters | |
(b) Directional & Gamma | 7.63 Meters | ||
Dog Leg Severity (per 100') | 90° per 100 capable | ||
Flow Range (gpm) | 75 gpm - 1100 gpm | ||
Max Operating Temprature | 175°C | ||
Max Bit Pressure (psi) | N/A | ||
Max Operating Pressure (psi) | 20,000 PSI | ||
Wireline Retrievable | Yes | ||
Pressure Drop Through Tool OD for Water | at 250 gal / min | 62.5 PSI | |
at 500 gal / min | 125 PSI | ||
at 1000 gal / min | 250 PSI | ||
Realtime update Period (sec) < or = 45 | Yes, Dependant on Pulse Width X Data Rate | ||
Survey Time (sec) < or = 180 | Yes, Dependant on Pulse Width X Data Rate | ||
Survey During Sliding Mode & Rotary Mode | Tool Face & Gamma Only | ||
Directional Measurement Point | With Gamma | 5.47 Meters | |
Without Gamma | 4.59 Meters | ||
Measurement Accuracy | Tool Face | +/- 0.25° | |
Azimuth | +/- 0.4° | ||
Inclination | +/- 0.1° | ||
Gamma Detector Type | APIGR | ||
Lost Circulation Material (Max Size & concentration) | 40 - 50 PPB Concentration & any size | ||
Power Source (Operating time, Hrs) | With Gamma | Approx 400 hrs | |
Without Gamma | Approx 600 hrs | ||
Gamma Realtime | Yes | ||
Gamma Measurement Point from Bottom of Tool | 2.52 Meters | ||
Recorded | Gamma Counts | ||
Data Transmission Rate | 0.25 - 3 Bits / Sec | ||
MTF / GTF Switch | Tool must be programmed at surface for automatic switch at desired inclination. ie, 5° | ||
Mean Time Between Failure | 2000 Hrs MTBF | ||
Repair Facility & Back-Up | Complete Tool Redundancy. Kit includes Purging, Testing & repair equipment. Technicians, Lab / re- pair facility. Repair technicians at charge pending availability. | ||
Manufacture / Model | Drill-Tek: DT001 |